Metric thresholds and target ranges in your Sonalix report
Last updated 5 min readTags:AnalysisSonalix
Look up the true-peak, stereo, dynamics and tonal thresholds that can produce a finding in your report.
A finding tells you which measured condition to check. Its importance tells you where to start. This page gives the figures behind those findings and identifies which come from meter validation, provisional product rules or reference releases.
True peak and export headroom
0 dBTP is full scale. Sonalix displays true peak in 0.1 dB increments. Its meter validation found errors of +0.2 dB high and −0.4 dB low. A reading in the first 100 ms can be about 0.5 dB high. The report accounts for those limits when it describes a measured peak.
| Reading | Premaster or finished master | Unfinished mix or unspecified stage |
|---|---|---|
| Over full scale, from +0.3 dBTP, or +0.8 dBTP in the first 100 ms | High | Medium |
| Near full scale, normally −0.3 to +0.2 dBTP | Medium | Low |
| Below full scale, at −0.4 dBTP or lower | Info, or low for a finished master above −1.0 dBTP | Info |
For a premaster comfortably below full scale, the info finding indicates delivery headroom. For a finished master, the −1.0 dBTP rule leaves margin because lossy encodes can raise peaks. The export check uses −1.0 dBTP as a default. If you enter a delivery ceiling, the report uses it and labels it required for your destination.
Stereo and mono checks
With Sonalix's power convention, negative left-right correlation means a loss of more than half the stereo power on fold-down. The report distinguishes a whole-track condition from one that appears briefly.
| Condition | Importance or use |
|---|---|
| Whole-track correlation below 0 | High |
| Correlation below 0 in the 20–120 Hz region | High |
| Correlation under 0.3 in the low region | Low if the high rule does not apply |
| Negative correlation in 3 s windows | Medium from 10% of the track, low from 3%, otherwise info |
| Negative correlation in bands at or above 120 Hz | Low |
| Low-band correlation of at least 0.9 and left/right balance within 1.0 dB | Low end described as centred |
| Mono-sum change of −1.5 dB or better, with no negatively correlated passage | Info |
The 0.3, 0.9, 1.0 dB and −1.5 dB cut-offs are provisional. In the reference set used for the passage rule, 22 of 44 tracks had a negatively correlated passage. On 20 of those, it occupied under 10% of the track. Listen at the time shown to see which part changes in mono.
Optional limiter comparison
The optional listening check requires all three conditions.
| Metric | Cut-off |
|---|---|
| Integrated loudness | At least −9.0 LUFS |
| PLR, or true peak minus integrated loudness | 7.5 dB or less |
| True peak minus maximum 3 s loudness | 5.5 dB or less |
Fewer than 1 in 20 of the 52 commercial releases used for this check measured that dense on either peak-to-loudness measure. By comparison, 22 of the 52 measured at least −11 LUFS with PLR of 10 dB or less. The finding has low importance and low confidence. Level readings cannot reveal which processor, if any, produced them. Compare with the limiter bypassed at matched volume.
Tonal thresholds
Sonalix compares the mix with the median of the selected reference balance. The general balance pools 33 releases. Pop has 6, hip-hop 5, electronic 6, house 8 and rock 8. The preceding hand-set curves produced tonal findings for all 44 usable references, with high findings for 24. The measured ranges reflect how varied released music can be, especially in the sub-bass.
The first reporting points below use the 90th percentile of distance from each reference's own genre median. Sub-bass can vary by more than 10 dB among releases of the same genre.
| Region | Deviation first reported (dB from median) | Build-up first reported (dB) |
|---|---|---|
| Sub-bass (20–45 Hz) | 11.5 | 9.5 |
| Bass (45–120 Hz) | 4 | 7 |
| Low mids (120–400 Hz) | 3 | 4.5 |
| Mids (400–1,000 Hz) | 3 | 5 |
| Upper mids (1,000–3,500 Hz) | 2.5 | 4.5 |
| Presence (3,500–8,000 Hz) | 4 | 4.5 |
| Top end (8,000–16,000 Hz) | 4.5 | 4.5 |
Low, medium and high tonal deviation start at 2.5, 4.0 and 6.5 dB beyond the region's tolerance. A narrow resonance is low from 7.0 dB above its neighbours and medium from 8.5 dB. In the calibration set, 43% of releases had a narrow point at least 5 dB above its neighbours and none reached 8 dB. The report labels working thresholds provisional and states that they were not validated by listening.
For a genre with one to four references, Sonalix moves the general balance halfway towards its examples, adds 1 dB of tolerance and caps tonal findings at medium. With no usable references it uses the named fallback and the same cap. With no genre selected, it uses the general balance with 0.5 dB extra tolerance. If a card suggests EQ, the mix-bus gain change is capped at 6 dB.
Delivery specifications and report readings
Integrated loudness, true peak, PLR and LRA do not have commercial-reference targets in Sonalix. Integrated loudness and LRA are contextual readings. An integrated loudness reading does not trigger a finding on its own.
Spotify uses Normal at −14 LUFS, Loud at −11 and Quiet at −19. It advises true peaks below −1 dBTP, or below −2 dBTP for masters louder than −14 LUFS. EBU R 128 recommends −23 LUFS programme loudness, with ±0.5 LU where exact normalisation is impractical in post-production, and a maximum true peak of −1 dBTP for linear audio in production. Use the specification for your destination if it gives one.
See how Sonalix measures your mix for windows and tolerances, or your mix report for how to use a finding.